Item Test Project Product Matching Technical Specifications
Transformer Transformer winding resistance measurement 20A DC Resistance Tester Output 20A, 1μΩ~2kΩ, Class 0.2 ±2 digits
  Transformer turns ratio and VT measurement Automatic Turns Ratio Tester Measuring range: 1~10000, Class 0.2
  Insulating oil withstand voltage test KDJJC-80 Automatic Oil Tester Voltage: 80kV, Accuracy 1%
  Insulating oil dielectric loss measurement Variable Frequency Dielectric Loss Tester Variable frequency output: 0.5~10kV (45/55/60/65Hz)
  Transformer short-circuit impedance & load loss, no-load current & loss, capacity measurement Transformer No-Load/Load & Capacity Tester Output: 0~100A, 0~750V
  Transformer on-load tap-changer measurement Transformer On-Load Tap-Changer Tester Range: 0~40Ω, 0~900ms
  Winding deformation measurement Transformer Winding Deformation Tester Output: 1k~2MHz (frequency response method)
Switchgear & GIS Circuit resistance measurement of switchgear and GIS 200A Loop Resistance Tester Output: 100~200A, Range: 0~2999.99μΩ
  Mechanical characteristics of circuit breakers / SF6 switches High Voltage Switch Dynamic Characteristic Tester Range: 0~75m/s, 0~900mm
  Vacuum degree measurement Vacuum Switch Vacuum Tester Range: 10⁻⁵~10⁻¹ Pa
Instrument Transformers Induced withstand voltage test for voltage transformers 20kVA Triple-Frequency Generator Capacity: 20kVA
  VA characteristic test CT/PT Characteristic Tester Measures angle error, ratio error, excitation characteristics, etc.
Arrester DC withstand voltage & DC leakage measurement; arrester DC reference voltage & leakage current test 200kV/2mA DC High Voltage Generator Output: 200kV, 2mA
  Arrester resistive current measurement; active & reactive component measurement Zinc Oxide Arrester Tester Output: 0~100V, Current: 0~10mA
Grounding Grid Grounding grid resistance measurement 5A Large Grounding Grid Resistance Tester Output: 5A, Range: 0~15Ω
Transformer Neutral Point Grounding Grounding lead conductor continuity test 20A Grounding Lead Conductor Tester Output 10A: 1μΩ~2Ω; 20A: 1μΩ~1Ω
Ground Resistance Ground resistance measurement 2571 Digital Ground Resistance Tester Resolution: 0.001Ω, 0.01Ω, 0.1Ω, 0.01V
Cable Fault Location Cable fault detection Cable Fault Tester Range: 0~15km, Resolution: 1m
Withstand Voltage for Transformer & HV Cable AC resonant withstand voltage for 400kVA/128kV XLPE cable Resonant Test System Suitable for 35kV XLPE cable up to 3000m; 110kV XLPE cable up to 1000m
GIS SF6 gas leak detection XP-1A SF6 Gas Leak Detector (qualitative) Leakage rate: 3 grams/year
  SF6 moisture content test SF6 Micro-Water Tester Dew point accuracy: ±0.5°C
  Withstand voltage test for GIS 270kVA/270kV GIS AC Resonant Test System Output: 0~270kV, Capacity: 270kVA
Other Comprehensive protection relay tester 1200A Microcomputer Relay Protection Tester Output: 6-phase current, 6-phase voltage
  Test voltage measurement 300kV AC/DC Voltage Divider Output: AC/DC 0~300kV
  Insulation resistance measurement of transformer windings & absorption ratio Intelligent Dual-Display Insulation Resistance Tester Output: 500~10000V; Range: 5000V/0~200GΩ; 10000V/0~400GΩ
  Current injection check (temperature rise test) 5000A High Current Generator Output current: 0~5000A
  Capacitance measurement (capacitor banks) Automatic Turns Ratio Tester (used for capacitance test) Rated output: 22V/25A/500VA; Measures capacitors without disconnecting connections, three-phase simultaneous, accuracy ±0.5%