Tech News

Tech News

KD-500L Automatic Capacitance and Inductance Tester: Function Analysis and Application Scenarios

KD-500L Automatic Capacitance and Inductance Tester: Function Analysis and Application Scenarios
15 Oct-2026

In reactive power compensation systems of substations, parallel capacitor banks and reactors are core equipment. Whether the capacitance value of capacitor banks meets the standard and whether the inductance of reactors is normal directly affects the reactive power compensation effect and system voltage quality. Traditional capacitance measurement requires disconnecting wires, which involves a large workload and risks damaging capacitors. The KD-500L automatic capacitance and inductance tester is designed to address this problem.

I. Measurement Without Disconnecting Wires — Solving an On-Site Pain Point

The core advantage of the KD-500L is that it can directly measure the capacitance of a single capacitor without disconnecting wires. The principle is to set up voltage and current sampling circuits in the capacitor branch under test, obtain current signals through a mobile current sampling unit, and combine them with voltage signals. After passing through a phase detector, the phase difference is output to the CPU for capacitance calculation.

This design solves three typical on-site problems: first, it avoids the workload and capacitor damage risk caused by disconnecting wires; second, it uses a measurement voltage of AC 26V/500VA, which is higher than ordinary capacitance meters, significantly improving fault detection capability; third, it also meets the measurement needs of reactor inductance.

II. Technical Parameters and Measurement Capability

The main technical specifications of the KD-500L are as follows:

  • Capacitance range: 0.2μF–2,000μF, capacity range 5–20,000 kvar. Accuracy: ±1% reading ±0.02μF for 0.2μF–2μF; ±1% reading ±2 digits for 2μF–2,000μF.

  • Inductance range: 1mH–9.99H, accuracy ±1.5% reading ±2 digits.

  • Output measurement voltage: AC 26V/500VA, 50Hz.

  • Display and storage: 320×240 large-screen LCD, full Chinese menu operation, can store 7,168 test data records.

  • Power supply and dimensions: AC 220V±10%, 50Hz; dimensions 370×370×220mm, weight 16kg.

III. Functional Features

Automatic range switching. The range is automatically selected during measurement, avoiding errors caused by manual operation and providing better stability and repeatability.

Simultaneous waveform and data display. The instrument can display voltage and current waveforms and phase relationships on the same screen, making the testing process more intuitive and facilitating quick on-site judgment.

Live measurement of coupling capacitors. The current measurement unit can also be used for measuring CVT, surge arresters, and other equipment, providing multiple functions in one instrument.

Discharge resistor measurement. It has a discharge resistor measurement function to determine whether the discharge circuit is normal.

Data printing and storage. The panel-mounted thermal printer can print test data on site. Local storage combined with USB storage meets data archiving requirements.

IV. Typical Application Scenarios

The KD-500L is mainly suitable for the following scenarios:

  • Substation parallel capacitor bank testing: Measure the capacitance of individual capacitors to determine capacity attenuation or internal component damage. The measurement-without-disconnecting-wires method is particularly suitable for on-site work with a large number of capacitors and limited power outage time.

  • Reactor inductance measurement: Used for inductance testing of series reactors and current-limiting reactors to determine whether there is inter-turn short circuit or inductance change.

  • Coupling capacitor and CVT testing: Using the current measurement unit, live measurement can be performed on coupling capacitors and capacitor voltage transformers.

  • New commissioning acceptance and fault diagnosis: Quickly obtain capacitance and inductance data during new capacitor bank commissioning acceptance, regular preventive testing, and troubleshooting.

V. Usage Notes

Before measurement, confirm that the capacitor bank has been fully discharged. Although the instrument supports measurement without disconnecting wires, it is still necessary to ensure that the branch under test is in a safe state. During testing, pay attention to the clamp direction of the current sampling unit to ensure accurate signal acquisition. The measurement environment temperature should be controlled within 0°C to +40°C, and relative humidity should be ≤90%. The instrument should be calibrated regularly to ensure accurate and reliable measurement data.

Conclusion

The KD-500L automatic capacitance and inductance tester provides an efficient and convenient solution for on-site testing of substation parallel capacitor banks and reactors through functions such as measurement without disconnecting wires, automatic range switching, and simultaneous waveform display. For specific technical parameters or configuration options, please contact us.

Wuhan KEDE Zhongwei Electric Co., Ltd.

Tel: 027-86861986

Email: whkdz@163.com

Address: No. 158 Huanhu Middle Road, Dongxihu District, Wuhan